Roberto
Posted 1149650103
Reply with quote
#1
I have an AU 517 which I really like. It looks in very good shape outside and inside. I have had it for about six months. It had worked fine until yesterday. I lost sound in one of the channels when I turned it on. I cannot figure out what the problem is and there was no apparent reason for this problems. I tried today again and there was sound in both channels for the first minute, but when I moved the balance dial to check the two channels, the sound disapeared again in the same channel as before. I never abuse the amplifier and I only use it one or two hours a day. Does anyone have any idea what the problem could be?
Thank you for your help,
Roberto
Keeper
Posted 1149665562
Reply with quote
#2
Quote:
Originally Posted by
Roberto I have an AU 517 which I really like. It looks in very good shape outside and inside. I have had it for about six months. It had worked fine until yesterday. I lost sound in one of the channels when I turned it on. I cannot figure out what the problem is and there was no apparent reason for this problems. I tried today again and there was sound in both channels for the first minute, but when I moved the balance dial to check the two channels, the sound disapeared again in the same channel as before. I never abuse the amplifier and I only use it one or two hours a day. Does anyone have any idea what the problem could be?
Thank you for your help,
Roberto
Try to clean your amp. I believe it's oxides in the signal path.
With the unit unplugged, clean all the pots and switches and the PRE OUT/MAIN IN jumpers using a good contact cleaner like Caig DeoxIT. With the unit still unplugged, work each and every control, switch and jumper several times. Make sure you have cycled everyting through all positions and ranges a dozen times or more.
Roberto
Posted 1149713394
Reply with quote
#3
Thank you for the suggestion. I will follow it.
lawman
Posted 1182079893
Reply with quote
#4
I've got an AU717 which met similar problem some time earlier. At first, I could not figure out what happened. I guessed it was the input stage that went wrong - poor contact. You know, for an ampliier that aged 30 years, this could be the most possible reason. Despite the heavy weight, I took it to a repair shop for an overhaul. When the boss of the shop called me to have it back, I happily took it home, assuming that it was alright (Actually, I had it tested before I paid. Yet, when I had it installed back to my rack, the same problem resumed. I checked and checked all over again. It was not until I gave up that I turned to the rear portion of the amplifer to check a switch that might went wrong. Bingo! It's the switch that separates this integrated amplier into a pre-amp and a power amp that goes faulty. My solution is very simple - either replace the switch or to abandon it by using an RCA cord that links the pre-amp stage and the power-amp stage. The whole problem immediately gets resolved. You guy may try to see if there is such a switch in your AU-515 and do the same checking like what I did! Good luck to you! Lawman Hong Kong
roberto Sanchez
Posted 1183262921
Reply with quote
#5
I need to replace the two major capacitators and transistors in the F2721 and F2722 boards of my AU 517. These are the two big capacitators in each of the boards. They are capacitators C11 and C14 but the service manual does not list a part number for them. The transitors are the two major transitors connected to each of these boards. The numbers in the back of the transistors are 25A745A and 25C1403A. I believe these are transistors 606 and 607 in the diagram. Any suggestions about a good brand of capacitators and transistors and where I could order them will be appreciated.
Roberto Sanchez
Keeper
Posted 1183480195
Reply with quote
#6
Quote:
Originally Posted by roberto Sanchez I need to replace the two major capacitators and transistors in the F2721 and F2722 boards of my AU 517. These are the two big capacitators in each of the boards. They are capacitators C11 and C14 but the service manual does not list a part number for them. The transitors are the two major transitors connected to each of these boards. The numbers in the back of the transistors are 25A745A and 25C1403A. I believe these are transistors 606 and 607 in the diagram. Any suggestions about a good brand of capacitators and transistors and where I could order them will be appreciated. Roberto Sanchez
C11 and C14 are both 470uF/63V which is the value you need. The Power Transistors are 2SA745A/2SC1403 but almost impossible to find. There are counterfeits on the market ao be careful. They don't have No 606 and 607 in my schematicYou can use OnSemi (Motorola) MJ21193 (pnp) and MJ21194 (npn).
roberto Sanchez
Posted 1183559785
Reply with quote
#7
Thank you for this information. Any suggestions where I could order them.
Keeper
Posted 1183560483
Reply with quote
#8
Quote:
Originally Posted by roberto Sanchez Thank you for this information. Any suggestions where I could order them.
http://www.digikey.com/ orhttp://www.mouser.com/
roberto Sanchez
Posted 1185855302
Reply with quote
#9
Thank you Keeper. I changed the capacitors and transistors and the problem disapeared for a a few days but it just began again: the amplifier turns on but it cannot pass the security check (a click and a blinking red light). The capacitors I changed had clear signs of corrosion. I also replaced two other capacitors in the main power board also with signs of corrosion. The rest of the capacitors appear to be in good shape. Any suggestions about other possible sources for this problem.
Thank you
Keeper
Posted 1185865026
Reply with quote
#10
Quote:
Originally Posted by roberto Sanchez Thank you Keeper. I changed the capacitors and transistors and the problem disapeared for a a few days but it just began again: the amplifier turns on but it cannot pass the security check (a click and a blinking red light). The capacitors I changed had clear signs of corrosion. I also replaced two other capacitors in the main power board also with signs of corrosion. The rest of the capacitors appear to be in good shape. Any suggestions about other possible sources for this problem. Thank you
How about Bias setting and DC at output
Roberto Sanchez
Posted 1186000243
Reply with quote
#11
Keeper, Thank you for your answer. Before changing the capacitors we checked DC at output and voltage in the test point in the circuit was negative triggering the protection sequence. After changing the capacitors and transistors the protection sequences worked ok and the amplifier operated normally so we did not meassure the DC at output. We assumed there was none since the amplifier was working ok.
treehugger
Posted 1186282644
Reply with quote
#12
I too have had recent problems but with the Sansui AU-717. On my first unit I would intermittently lose one channel, but could get it back by going 2,3, or 4 clicks up in volume (from my normal low listenting level of the very first upwardclick position). Then the other channel would go out, but I could reclaim it once again by raising the volume up a few clicks and then back. Every time I powered it up I would have to go through this ritual 5, 6 7...times. Eventually both channels would play without further problem...until I turned the unit off and powered up again. Then it started all over. I had the unit replaced by the seller as I have a one year warranty against failure. The second unit played flawlessly for one week and two hours when the right channel dropped out and stayed out. The seller feels that that there is a fault in my speakers, Klipsch RF-35, 8 ohm rating, 98 db sensitivity. However I play two other vintage integrated amps through the same speakers ( tuners, cd players and vinyl) without problem. Personally I think the speakers are okay, but how to prove it without having to haul over 100 lbs of speakers and pay someone to technically measure the impedance across each woofer while under load? The Sansui AU-517 / 717 is the best amp my poor ears have yet heard but I am worried that it may just be impossible to expect one to last very long.
Keeper
Posted 1186311767
Reply with quote
#13
First thing todo with a 30+ amplifier is to clean all switches. After so many years oxide is building up and kill the signalo path. Use Caig DeoxIT D5
Treehugger
Posted 1186362853
Reply with quote
#14
Thanks Keeper Both of the Sansui AU-717 units mentioned were fully serviced. The first unit which was returned to the seller has played withoutr problem on his bench. I was hoping someone would respond to my last three paragraphs, i.e., is it really possible for Klipsch RE-35's, two way floorstanding units, 8 ohms, 98db, to present a problem to the AU-717? Klipsch says they are 8 ohm rated, but depending on volume and frequency, the impedance across the woofers may instantaneously fall to low levels for a very short fraction of a second. I really love the sound of the AU-717, but if my speakers are the cause of the problem, I will have to pass on the 717. Do all of the 70's Sansui amps need pure 8 ohm loads?
Sean
Posted 1192713827
Reply with quote
#15
Not sure if this thread is dead or not, but I can give some further input. I have an AU 517 and am experiencing some of the same issues... Power Faulting... Right channel loss... bla bla bla... I noticed that if I turn on the amp in preamp mode, and then turn it to normal mode, it will start fine. But once I play some music it will click off after 5 minutes or so... At first I thought it was heat related... But after reading this thread, I now think that it is the amp select switch on the back. As for the channel loss, I found it was because my RCA's were being bushed upon by my wall, so I moved the amp further away from anything to allow the RCA's to hang without any forces or pull acting on them. And this fixed my channel issues. I am going to try and clean my switches and see what happens.